circuit_solution.gif
logo_header5.gif

 October 18, 2004 - Issue 18

 

more_info_logo.gif



See us at IBEX
 
IBEX_logo.jpg
 
Blue Sea Systems will be in booth number 332. Stop by to see the new WeatherDeck™ panel and BatteryLink™ ACR.


more_info_logo.gif

See us at METS
 
mets_logo.jpg
 
See us at METS, November 16th–18th, in booth number 08.058.


more_info_logo.gif

Updated Water Resistant Fuse Panels
 
water_resistant_panels.jp
 
 
Our water resistant fuse panels have been updated with a new fuse holder and gasket. This improves the water resistance of the panel and makes fuse removal and replacement easier.
The change affects Blue Sea Systems part numbers 8053, 8054, 8261, 8262, 8055, 8263, 8356, and 8353.


new_product_logo.gif

New WeatherDeckâ„¢ Water Resistant Panels
 
weatherDeck_Panels.jpg
 
Blue Sea Systems is introducing our new WeatherDeckâ„¢ water resistant panels at IBEX. These stylish panels can be mounted in 4 different orientations. The panels use ATO/ATC blade style fuses and feature bi-colored LED's to indicate "ON", "OFF", or a "Blown" fuse. Available in 2, 4, 6, and 8 position models in Gray or White.
For more information, please click here.


new_product_logo.gif

New BatteryLinkâ„¢ ACR
 
7600.jpg
 
New for 2005 is the BatteryLinkâ„¢ ACR. It automatically connects battery banks during the charging cycle and disconnects during discharge. It also functions as a current limiter so smaller wire can be used. The open and close voltage is adjustable as well as the high voltage cutout. It is ignition protected for safe installation on gasoline powered boats.
For more information, please click here.


application_brief_logo.jp

Battery Isolators and Automatic Charging Relays

Battery Isolators, Automatic Charging Relays (also called ACR’s , combiners, or voltage sensitive relays) are all intended to keep a load (or loads) from discharging the reserve battery system.  The reserve battery system is used for vital loads like engine starting, navigation or communications. Battery Isolators and ACR’s are intended to distribute current from a charging source to all batteries, but leave the batteries isolated during discharge conditions so they are only impacted by their own loads.

Battery Isolators are made with two or more silicon diodes that act like check valves. The diodes will pass current from the charging source to the batteries, but will not pass current backward from one battery to the other or back to the charging source. Nature extracts a price for this by causing a voltage drop of about 0.7 Volts across the diodes. If you have a regulated charging source that senses its own output, the voltage at the battery will be lower than at the charger or regulator and, if not compensated for, will lead to inadequate charging.

ACR's or Automatic Charging Relays are automatic switches that close when the voltage on one of the batteries rises to a level (normally 13.2V to 13.7V) indicating the battery is connected to a charge source and is partially or fully charged. The switch then closes and shares the charging current with the other battery until the voltage drops to some lower level (normally 12.4 to 13.1 depending on model) and the switch opens. This prevents discharging both batteries when there is not enough current to charge both batteries.

With the ACR or an isolator, the batteries are effectively connected together during charging and disconnected during discharge. The isolator is the simpler of the two approaches, when used with remote sensing chargers and regulators, but without remote sensing the isolator gives poor performance.

The ACR simplifies the system design because chargers and regulators that work with a single battery bank will still work with a multiple battery bank. Outboard motors and inverter / chargers have a single line that provides charge current, but can also absorb starting current or inverter current. They can't be connected through an isolator because the isolator will not permit the backward flow of energy when the source becomes an intended load.

There is an issue with multi-stage chargers which cut back to a lower charging voltage for "float." If the charger is supplying one lightly loaded battery directly and supplying a second battery through an ACR, and the second battery is the one that gets loaded, the system may not respond. The voltage of the first battery can be too low to trigger the ACR during the float stage while the loaded battery is being discharged. Because the ACR does not close, the multi-stage charger cannot see that the second battery needs charging current. This is usually resolved by connecting the multi-stage charger to the battery that has a load connected instead of connecting to the unloaded bank.  Many multi-stage chargers also come with multiple outputs and the second output can be helpful in this situation and avoid loss of charge during the float stage.

ACR’s and Battery Isolators are a valuable addition to a battery management system and simplify charging multiple battery banks while protecting the reserve battery system.  Below is a diagram of an ACR used in a two battery system.
 
8280.jpg


You are receiving this newsletter from Blue Sea Systems because you have contacted us or subscribed on our website.

If you wish to unsubscribe, please send an E-mail to listmaster@bluesea.com with the word REMOVE as the subject.

If you’ve received this newsletter from a third party and you wish to subscribe to Blue Sea Systems' eNewsletter, please send an E-mail to listmaster@bluesea.com with the word SUBSCRIBE as the subject.

Blue Sea Systems would like to hear from you regarding any questions you may have, or any suggestions for publication in future editions of the Circuit Solutionsâ„¢ Newsletter. Please send us your suggestions to: listmaster@bluesea.com.

Copyright ©2004 - Blue Sea Systems, Inc.
425 Sequoia Drive, Bellingham, WA 98226 USA
Phone: 360-738-8230
Fax: 360-734-4195
Website: www.bluesea.com