SI-Series

SI-ACR Automatic Charging Relay - 12/24V DC 120A

7610REV000
Discontinued - replaced by PN 7610 undervoltage lockout changed (3/2012)
  • Protects sensitive electronics by temporary isolation of house loads from engine circuit during engine cranking
  • Designed for 12 or 24 volt systems
  • 12/24 volt auto ranging voltage input
  • Hermetically sealed contacts/vaporproof
  • Waterproof rated IP67—temporary immersion for 30 minutes
  • Ignition protected—safe for installation aboard gasoline powered boats
  • Remote LED output indicates relay state away from ACR
  • Supports high-output alternators up to 120 Amperes
  • Dual sensing
Compare
Specifications
Nominal Voltage12V DC
24V DC
Start Isolation Yes
Amperage Operating Current175mA (combined)
15mA (open)
Terminal Stud Torque140 in-lb (15.82 Nm)
Continuous Rating 120A
Intermittent Rating 210A (5 min)
Cable Size to Meet Ratings1/0 AWG
Terminal Ring Diameter Clearance1.12in (28.45 mm)
Terminal Stud Length1.50in (38.1 mm)
Terminal Stud Size3/8" - 16 (M10)
Relay Contact PositionSPEC_HEADER
Combine 30 sec13.6V @ 12 V
27.2V @ 24 V
Combine 90 sec13.0V @ 12 V
26.0V @ 24 V
Open 10 sec12.35V @ 12 V
24.7V @ 24 V
Open 30 sec12.75V @ 12 V
25.5V @ 24 V
Open High16.0V @ 12 V
30.0V @ 24 V
Over Voltage Lockout16.0V @ 12V
32.0V @ 24V
Under Voltage Lockout 10.8V @ 12 V
21.6V @ 24 V
Weight1.25lb (0.57 kg)
Meets the following Regulatory Specifications
CE Marked
Ignition Protected
IP67
ISO 8846
SAE J1171
UL 1500