Products are now organized by Electrical System Divisions
 
Previous Blue Sea Systems' catalogs grouped products together by type, leaving it to the customer to determine where in the electrical system their use was appropriate. This often required in-depth study of each product's technical specifications. To eliminate this burden, products in this catalog are grouped according to the part of a boat's electrical system in which they are used. Implicitly, the American Boat and Yacht Council (ABYC) Standards divides a boat's electrical system into four divisions:
 
1. DC Main Power Distribution
2. DC Branch Power Distribution
3. AC Main Power Distribution
4. AC Branch Power Distribution
 
Although this division is explicit in the Standards only for circuit breakers and uses, it exists in fact for most marine electrical circuit components. An electrical component's amperage and voltage ratings, functionality and physical configuration generally restrict its main uses to one of these four divisions. To assist users of this catalog to understand the four divisions of the marine electrical system and to quickly identify the products appropriate to each, the 2004 catalog presents most Blue Sea Systems' products divided into one of these four Electrical System Divisions, with a technical introduction to each division.


application_brief_logo.jp

New 120/240 Volt Panels
 
Blue Sea Systems now offers five 120/240 volt panels. One is a 240V AC main breaker only. The other four panels have 240V AC main circuit breakers, Digital or Analog meters, and 240V AC branch circuits. Two of the panels provide 240V AC source selection for 2 sources. They can function as 240V AC panels with main and branch circuit protection or can be used in conjunction with 120 volt AC panels for 120V AC branch circuit distribution.

The panels have 3 pole main circuit breakers and double pole branch circuit breakers. 240V AC supplies consist of 2 hot lines, one neutral line, and ground. Between the 2 hot lines the voltage measured is 240V AC. Between either one of the hot lines and neutral the voltage measured is 120V AC. This allows each hot line to supply a 120V AC source if needed.
 
The panels can supply 240V AC branch circuits or 2 120V AC load groups whether they are 2 separate AC branch distribution panels or a panel with 2 separate load groups. An example of this configuration is the Blue Sea Systems 7370 120/240V AC panel supplying two 8480 120V AC panels, see Fig. 1. Another option is to use 7370 120/240V AC panel supplying an 8461 120V AC panel, dividing the 120V AC legs between the 2 columns of breakers, see Fig. 2.
 
Fig. 1
newsletter_17_fig1.jpg
 
 
Fig. 2
newsletter_17_fig2.jpg
 
For details about the installations, please consult the panel instructions. See our new catalog or website for our full selection of electrical distribution panels.


more_info_logo.gif

New!
High and Low Voltage Alarm on the 8247 AC Multimeter
 
8247.jpg
 
Blue Sea Systems 8247 AC Digital Multimeter now has a high and low voltage alarm which is both audible and visual. The alarm values are user settable for their needs to warn of under or over voltage situations. The meter will measure from 70-300V DC and 0-150 Amps. The meter includes a high amperage alarm also. The alarms are set by the user for their needed voltage and amperage requirements. Blue Sea Systems digital multimeters also include a scan function which cycles the display between the different items measured.
 
For more information, please click here.


more_info_logo.gif

New Product
Automatic Charging Relay
 
9112.jpg
 
The Automatic Charging Relay (ACR) will automatically connect two battery banks during the charging cycle and disconnects under discharge. It recognizes both 12V and 24V DC systems without any reconfiguration. The ACR automatically closes when a charging voltage on either battery is present for at least 30 seconds. The ACR opens when the voltage drops below the charging voltage to prevent accidental discharge of an unintended bank.
 
The ACR has a manual override to cross connect battery banks for engine starting. There is an output for an "ON" indicating LED to remotely monitor when the contacts are closed. When combined with an "ON"-"OFF"-"ON" switch the ACR can be turned off, set to automatic, or manually closed. A sample application is below in fig. 3.
 
9112_chart.gif
 
Fig. 3
newsletter_17_fig3.jpg
 
For more information, please click here.



You are receiving this newsletter from Blue Sea Systems because you have contacted us or subscribed on our website.

If you wish to unsubscribe, please send an E-mail to listmaster@bluesea.com with the word REMOVE as the subject.

If you’ve received this newsletter from a third party and you wish to subscribe to Blue Sea Systems' eNewsletter, please send an E-mail to listmaster@bluesea.com with the word SUBSCRIBE as the subject.

Blue Sea Systems would like to hear from you regarding any questions you may have, or any suggestions for publication in future editions of the Circuit Solutionsâ„¢ Newsletter. Please send us your suggestions to: listmaster@bluesea.com.

Copyright ©2004 - Blue Sea Systems, Inc.
425 Sequoia Drive, Bellingham, WA 98226 USA
Phone: 360-738-8230
Fax: 360-734-4195
Website: www.bluesea.com