Menu
Blue Sea Systems
  • Products
    • Power Conversion
      • Battery Chargers
      • USB Chargers
      • Connectors
      • Dimmers
      • Air Brake Compressors
    • Automatic Charging Relay
      • Non-Critical Load Disconnects
      • Automatic Charging Relays
    • Battery Switches
      • Manual Battery Switches
      • Battery Management Panels
      • Remote Battery Switches
    • Solenoids
      • L-Series
      • ML-Solenoids
    • BusBars and Insulators
      • BusBars
      • Terminal Blocks
      • PowerPost Connectors
      • Feed Through Connectors
      • Insulators
      • Cable Clams
    • Fuses and Fuse Blocks
      • Fuses
      • Fuse Holders
      • Fuse Blocks
    • Circuit Breakers
      • Push Button Reset-Only
      • Medium Duty
      • 285-Series
      • 187-Series
      • A-Series
      • C-Series
      • ELCI and GFCI
      • UL-489
      • ATO-ATC Style Low Profile
      • Marine Grade Short Stop
      • Surface Mount System
      • Circuit Breaker Blocks
      • Accessories
    • Panels
      • DC Panels
      • AC Panels
      • ACDC Panels
      • Custom Panels
      • Panel Accessories
      • Labels
    • Meters
      • Analog Meters
      • Digital Meters
      • OLED Digital Monitors
      • Mini OLED Digital Monitor
      • Clamp
      • Shunts
      • Accessories
    • Switches
      • Contura Switches
      • Toggle Switches
      • Rocker Switches
      • Push Button Switches
      • Rotary Switches
      • Accessories
  • Where to Buy
  • Support
    • Technical Help
      • Articles
      • Reference
      • Documents
    • System Diagrams
    • Marketing Materials
      • Catalog
      • Apparel
      • Posters
      • Product Guides
      • Sales Sheets
      • Product & Price Lists
      • Product Images
    • Newsroom
      • Press Room
      • Newsletters
      • News Releases
    • ABYC C7 Compliance
    • Warranty Registration
    • Authorized Internet Reseller Program
  • About Us
  • Circuit Wizard
  • Panel Wizard
  • Order Labels
    • Browse Labels
  • View Catalog

Four Stage Battery Charging With Prefloat Explained

October, 12 2012
Found this article helpful?
Get the latest when you sign up for our newsletter!
Follow @BlueSeaSystems
  1. Bulk charges batteries to 75-80% of full charge.
  2. Absorption gradually completes remaining charge to full.
  3. PreFloat moves each battery individually from Absorption to PreFloat, based on the need of the battery. This prevents overcharging and damage to the batteries. Up to 0.5V difference between Absorption and PreFloat voltages can be achieved.
  4. Float maintains battery charge.

Example of Flooded Lead Acid Battery

Conventional Battery Charges

Conventional battery chargers move all batteries from Absorption to Float simultaneously with no ability to adjust for individual battery requirements.



Example of Flooded Lead Acid Battery

Forced Absorption: A period when batteries are potentially over charged.