Automatic Charging Relay (ACR) Explained| Specifications | |
|---|---|
| Nominal Voltage | 12V DC 24V DC |
Start Isolation ![]() | Yes |
Continuous Rating ![]() | 120A |
Intermittent Rating ![]() | 210A (5 min) |
| Amperage Operating Current | 175mA (combined) 15mA (open) |
| Cable Size to Meet Ratings | 1/0 AWG |
| Terminal Ring Diameter Clearance | 1.12in (28.45 mm) |
| Terminal Stud Length | 1.50in (38.1 mm) |
| Terminal Stud Size | 3/8-16 (M10) |
| Terminal Stud Torque | 140 in-lb (15.82 Nm) |
| Relay Contact Position | SPEC_HEADER |
| Combine 30 sec | 13.6V @ 12 V 27.2V @ 24 V |
| Combine 90 sec | 13.0V @ 12 V 26.0V @ 24 V |
| Open 10 sec | 12.35V @ 12 V 24.7V @ 24 V |
| Open 30 sec | 12.75V @ 12 V 25.5V @ 24 V |
| Open High | 16.0V @ 12 V 30.0V @ 24 V |
| Over Voltage Lockout | 16.0V @ 12V 32.0V @ 24V |
Under Voltage Lockout ![]() | 9.5V @ 12 V 19V @ 24 V |
| Weight | 1.25lb (0.57 kg) |
| Included With | ||
|---|---|---|
| | 7650 | Add-A-Battery - 120A |
| Meets the following Regulatory Standards |
|---|
![]() ![]() ![]() ![]() ![]() |
| Previous versions of this product | |
|---|---|
| undervoltage lockout changed (3/2012) |